<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Ilam University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی ایلام</title_fa>
<short_title>J. Ilam Uni. Med. Sci.</short_title>
<subject>Medical Sciences</subject>
<web_url>http://sjimu.medilam.ac.ir</web_url>
<journal_hbi_system_id>96</journal_hbi_system_id>
<journal_hbi_system_user>journal96</journal_hbi_system_user>
<journal_id_issn>1563-4728</journal_id_issn>
<journal_id_issn_online>2588-3135</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>doi</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2018</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>25</volume>
<number>6</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی تاثیر محل تجمع اکتیویته در بیماران درمان شده با رادیوداروی ید-131بر اکسپوژر محاسبه شده در فواصل مختلف از بیمار با استفاده از فانتوم NCAT
</title_fa>
	<title>Verification of Activity Accumulation Location Effect in Patients Treated with I-131 Radio Pharmacy on the Evaluated Exposure at Different  Distances from Patient using  NCAT Phantom

</title>
	<subject_fa></subject_fa>
	<subject></subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Applicable</content_type>
	<abstract_fa>&lt;table align=&quot;left&quot; cellpadding=&quot;0&quot; cellspacing=&quot;0&quot; hspace=&quot;0&quot; vspace=&quot;0&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td align=&quot;left&quot;&gt;&lt;div style=&quot;text-align: justify;&quot;&gt;&lt;/div&gt;
			&lt;table align=&quot;left&quot; cellpadding=&quot;0&quot; cellspacing=&quot;0&quot; hspace=&quot;0&quot; vspace=&quot;0&quot;&gt;
				&lt;tbody&gt;
					&lt;tr&gt;
						&lt;td style=&quot;padding: 0in 9pt; vertical-align: top; text-align: justify;&quot;&gt;&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;مقدمه:&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt; &lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;یکی از معمول &amp;shy;ترین موارد استفاده از ایزوتوپ&amp;shy; های پزشکی، درمان سرطان و پرکاری تیروئید با استفاده از ید-131 است. ید-131 در سلول &#8204;های سرطانی تجمع کرده و واپاشی می&amp;shy;کند. بدیهی است که در این روش درمانی، توزیع مکانی و زمانی ماده رادیو اکتیو در بدن به صورت محسوسی می &#8204;تواند متفاوت باشد. هدف از این مطالعه بررسی تاثیر بالقوه نحوه توزیع ید رادیو اکتیو در بدن بر میزان اکسپوژر محاسبه شده در فواصل مختلف از بدن&lt;/span&gt;&lt;/span&gt; &lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;بیمار می باشد&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
						&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;مواد و روش&#8204; ها:&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt; &lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;این بررسی با استفاده از فانتوم&#8204; های &lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;NCAT&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt; بالغ، شبیه&amp;shy; سازی مونت کارلو و کد گیت انجام گرفته است. با اعمال اکتیویته&#8204; یکسان در اندام های مورد مطالعه فانتوم، جهت اندازه&amp;shy; گیری طیف انرژی و محاسبه اکسپوژر ناشی از اکتیویته&#8204; مذبور در فاصله&amp;shy;&amp;shy; یک، دو و سه متری از&amp;nbsp; فانتوم، از شبیه&#8204; سازی کد گیت استفاده گردید. بعد از استخراج مقادیر اکسپوژر و نمودارهای شدت انرژی برای پنج اندام مذکور، با استفاده از آزمون کولموگراف اسمیرنوف(&lt;/span&gt;&lt;/span&gt;&lt;span dir=&quot;LTR&quot;&gt;&lt;span style=&quot;font-family:times new roman,serif;&quot;&gt;KS&lt;/span&gt;&lt;/span&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;)، تیروئید را مبنا قرار داده و اختلاف طیف چهار عضو دیگر با آن محاسبه و مورد بررسی قرار گرفت.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
						&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;یافته &#8204;های پژوهش:&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt; &lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;نتایج شبیه&#8204; سازی نشان داد که اکسپوژر ناشی از اکتیویته موجود در پنج اندام مذکور در فاصله یک متر به میزان قابل ملاحظه&#8204; ای با یکدیگر متفاوت است در حالی که با افزایش فاصله به دو و سه متر، تفاوت اکسپوژر بسیار کاهش می &#8204;یابد. به عبارت دیگر، با افزایش فاصله، تاثیر محل تجمع ید رادیواکتیو بر اکسپوژر رسیده به فانتوم ناظر به&#8204; شدت کاهش می &amp;shy;یابد.&lt;/span&gt;&lt;/span&gt;&lt;/td&gt;
					&lt;/tr&gt;
				&lt;/tbody&gt;
			&lt;/table&gt;
			&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;div style=&quot;clear:both;&quot;&gt;&lt;/div&gt;&lt;strong&gt;&lt;em&gt;&lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;بحث و نتیجه &#8204;گیری:&lt;/span&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt; &lt;span style=&quot;font-family:b mitra;&quot;&gt;&lt;span style=&quot;font-size:11.0pt;&quot;&gt;با توجه به نتایج شبیه&#8204; سازی، برای بیمارانی که بعد از ترخیص از فواصل نزدیک با دیگران ارتباط خواهند داشت یا باید معیار اکسپوژر حد ترخیص به ازای هر کدام از پنج اندام بررسی شده به صورت مجزا تعیین شود و یا این که در صورت استفاده از یک معیار کلی واحد، دستورالعمل&#8204; هایی برای رعایت توسط افرادی که بعد از ترخیص از فاصله نزدیک با بیمار در ارتباط هستند، ارائه شود.&lt;/span&gt;&lt;/span&gt;&lt;br&gt;
&amp;nbsp;&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;div style=&quot;clear: both; text-align: justify;&quot;&gt;&lt;/div&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;/p&gt;&lt;p dir=&quot;ltr&quot;&gt;&lt;/p&gt;&lt;div style=&quot;clear:both;&quot;&gt;&lt;/div&gt;</abstract_fa>
	<abstract>&lt;table align=&quot;left&quot; cellpadding=&quot;0&quot; cellspacing=&quot;0&quot; hspace=&quot;0&quot; vspace=&quot;0&quot;&gt;
	&lt;tbody&gt;
		&lt;tr&gt;
			&lt;td align=&quot;left&quot;&gt;
			&lt;p&gt;&lt;strong&gt;&lt;em&gt;Introduction&lt;/em&gt;&lt;/strong&gt;: One of the most common applications of medical isotopes is in treatment of cancer and hyperthyroidism using Iodine-131. The Iodine-131 cumulates in cancerous cells and acts as a source of radioactive emissions. Apparently, local and temporal distributions of the radioactive material are different in various organs. In this paper, the effect of radioactive Iodine distribution on the amount of exposure at different distances has been investigated.&lt;br&gt;
			&amp;nbsp;&lt;br&gt;
			&lt;strong&gt;&lt;em&gt;Materials &amp; Methods&lt;/em&gt;&lt;/strong&gt;: This analysis has been carried out using adult NCAT phantoms, Monte-Carlo simulation, and GATE code. By applying the same amount of activity on five different organs of the phantom, the quality and quantity of energy has been computed as well as the amount of emitted exposures at distances of one, two, and three meters. Then, by setting thyroid as the basis, the difference of exposure emitted from other four organs has been calculated and analyzed using KS test.&lt;br&gt;
			&amp;nbsp;&lt;br&gt;
			&lt;strong&gt;&lt;em&gt;Findings&lt;/em&gt;&lt;/strong&gt;: Simulation results had been showed that the amounts of exposure that emitted from aforementioned organs are significantly different at the distance of one meter whereas this difference diminishes significantly at distances of two and three meters. In other words, the effect of radioactive Iodine integration location on the emitted exposure is being trivial as the distance increases.&lt;strong&gt;&lt;em&gt; &lt;span dir=&quot;RTL&quot;&gt;&lt;/span&gt;&lt;/em&gt;&lt;/strong&gt;&lt;br&gt;
			&amp;nbsp;&lt;br&gt;
			&lt;strong&gt;&lt;em&gt;Discussion &amp; Conclusion&lt;/em&gt;&lt;/strong&gt;&lt;strong&gt;s:&lt;/strong&gt; Distinct TEDE values must be defined for each of the aforementioned organs and confirmed before releasing patients who will be faced to the others at short distances. Otherwise, guidelines must be considered for the others who will be faced to the released patient.&lt;/p&gt;
			&lt;/td&gt;
		&lt;/tr&gt;
	&lt;/tbody&gt;
&lt;/table&gt;

&lt;p&gt;&lt;div style=&quot;clear:both;&quot;&gt;&lt;/div&gt;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;&lt;div style=&quot;clear:both;&quot;&gt;&lt;/div&gt;&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>سرطان تیروئید, پرکاری تیروئید, ید-131, اکسپوژر, فانتوم NCAT, شبیه‌ سازی مونت کارلو, کد GATE</keyword_fa>
	<keyword>Thyroid cancer, Hyperthyroidism, Iodine-131, Exposure, NCAT phantom, Monte-carlo simulation, GATE code</keyword>
	<start_page>54</start_page>
	<end_page>62</end_page>
	<web_url>http://sjimu.medilam.ac.ir/browse.php?a_code=A-10-2778-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mahin</first_name>
	<middle_name></middle_name>
	<last_name>Kokhazadeh</last_name>
	<suffix></suffix>
	<first_name_fa>مهین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>کوخازاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mahin_kookhazadeh@yahoo.com</email>
	<code>9600319475328460038749</code>
	<orcid>9600319475328460038749</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Dept of Physical Physic, Faculty o Medical Sciences, Tarbiatmodares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Rajabi</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رجبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hrajabi@modares.ac.ir</email>
	<code>9600319475328460038750</code>
	<orcid>9600319475328460038750</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Physical Physic, Faculty o Medical Sciences, Tarbiatmodares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Samira</first_name>
	<middle_name></middle_name>
	<last_name>Rasaneh</last_name>
	<suffix></suffix>
	<first_name_fa>سمیرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رسانه</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>srasaneh@aeoi.org.ir</email>
	<code>9600319475328460038751</code>
	<orcid>9600319475328460038751</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Institute for Research in Technology and Nuclear Science, Tehean, Iran</affiliation>
	<affiliation_fa>موسسه تحقیقات فناوری و علوم هسته ای، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohammad ali</first_name>
	<middle_name></middle_name>
	<last_name>Askari</last_name>
	<suffix></suffix>
	<first_name_fa>محمدعلی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عسکری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>Askari.tmu@hotmail.com</email>
	<code>9600319475328460038752</code>
	<orcid>9600319475328460038752</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Physical Physic, Faculty o Medical Sciences, Tarbiatmodares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Parisa</first_name>
	<middle_name></middle_name>
	<last_name>Taheri</last_name>
	<suffix></suffix>
	<first_name_fa>پریسا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>طاهری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>parisatahery@yahoo.com</email>
	<code>9600319475328460038753</code>
	<orcid>9600319475328460038753</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Physical Physic, Faculty o Medical Sciences, Tarbiatmodares University, Tehran, Iran</affiliation>
	<affiliation_fa>گروه فیزیک پزشکی، دانشکده علوم پزشکی، دانشگاه تربیت مدرس، تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
