<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Ilam University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی ایلام</title_fa>
<short_title>J. Ilam Uni. Med. Sci.</short_title>
<subject>Medical Sciences</subject>
<web_url>http://sjimu.medilam.ac.ir</web_url>
<journal_hbi_system_id>96</journal_hbi_system_id>
<journal_hbi_system_user>journal96</journal_hbi_system_user>
<journal_id_issn>1563-4728</journal_id_issn>
<journal_id_issn_online>2588-3135</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>doi</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>11</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>تاثیر ضخامت جبران کننده برنج و ابعاد میدان بر ضریب تضعیف موثر  جبران کننده در پرتو درمانی با شدت تعدیل یافته(IMRT)</title_fa>
	<title>Influence of Compensator Thickness and Field Size on the  Effective Attenuation Coefficient of a Brass  Compensator for Intensity-Modulated  Radiation Therapy</title>
	<subject_fa>فیزیک پزشکی</subject_fa>
	<subject>Medical physics</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt;یکی از روش های پرتودرمانی با شدت تعدیل یافته بر پایه استفاده از جبران کننده ها می باشد. مهم ترین عامل در ساخت جبران کننده محاسبه دقیق ضخامت آن به منظور دستیابی به شدت تعدیلی مورد نظر می باشد. به این منظور باید ضریب تضعیف دقیق ماده جبران کننده محاسبه شود. با استفاده از دزیمتر &lt;span dir=&quot;LTR&quot;&gt;2&lt;/span&gt; &lt;span dir=&quot;LTR&quot;&gt;MapCHECK&lt;/span&gt; مدل 1177و فانتوم آب جامد 34&lt;span dir=&quot;LTR&quot;&gt;SP&lt;/span&gt; تاثیر ضخامت جبران کننده برنج و اندازه میدان بر محاسبه ضریب تضعیف موثر جبران کننده برای باریکه فوتونی &lt;span dir=&quot;LTR&quot;&gt;MV&lt;/span&gt;6 یک شتابدهنده خطی پزشکی (&lt;span dir=&quot;LTR&quot;&gt;Elekta SL 75/25&lt;/span&gt;) بررسی شد. تمامی اندازه گیری ها در فاصله چشمه تا سطح (&lt;span dir=&quot;LTR&quot;&gt;SSD&lt;/span&gt;) 100 سانتی متر و عمق 5 سانتی متری برای اندازه میدان های &lt;span dir=&quot;LTR&quot;&gt;cm&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt; 1&amp;times;1 تا &lt;span dir=&quot;LTR&quot;&gt;cm&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt; 20&amp;times;20 و ضخامت های 5/0 تا 6 سانتی متر جبران کننده برنج انجام شدند. نتایج نشان دادند که با افزایش ضخامت جبران کننده و اندازه میدان، ضریب تضعیف موثر کاهش می یابد. بنا بر این می توان نتیجه گرفت که ضخامت جبران کننده و اندازه میدان پارامترهای مهمی در محاسبه ضریب تضعیف موثر برای باریکه فوتونی &lt;span dir=&quot;LTR&quot;&gt;MV&lt;/span&gt;6 می باشند، به طوری که در نظر گرفتن اثر این عوامل بر محاسبه ضریب تضعیف موثر سبب کاهش خطا در تحویل دز به عمق درمانی و &amp;nbsp;ارگان های بحرانی مورد نظر می شود.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;One of the intensity modulated radiation therapy (IMRT) methods is based on using compensators. The most important factor in designing a compensator is the accurate calculation of its thickness to achieve the intensity modulation of interest. To achieve that, the exact attenuation coefficient of compensator materials must be calculated.Using MapCHECK 2 model 1177 and phantom (SP34). We studied the effect of compensator thickness and field size on the calculation of the effective attenuation coefficient (EAC) of the brass compensator for 6-MV photon beams.&lt;/p&gt;

&lt;p&gt;Experimental measurements were carried out at 100 cm source-to-surface distance and 5 cm depth for the 6-MV photon beams of an Elekta &amp;nbsp;linac using various field size and compensator thickness. The field sizes investigated ranged from 1&amp;times;1 cm&lt;sup&gt;2&lt;/sup&gt; to 20&amp;times;20 cm&lt;sup&gt;2&lt;/sup&gt; and the brass compensator thickness from 0.5-6 cm. Our results indicated that the compensator thickness and field size have the most significant effect on the calculation of the compensator EAC for the 6-MV photon beam and also these parameters can reduce the error due to delivered dose to target volume and organs at risk.&lt;/p&gt;
</abstract>
	<keyword_fa>پرتودرمانی با شدت تعدیل یافته, جبران کننده, برنج, ضریب تضعیف موثر</keyword_fa>
	<keyword>Intensity modulated radiation therapy, Compensators, Brass, Effective attenuation coefficient</keyword>
	<start_page>61</start_page>
	<end_page>70</end_page>
	<web_url>http://sjimu.medilam.ac.ir/browse.php?a_code=A-10-2472-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Elnaz</first_name>
	<middle_name></middle_name>
	<last_name>Balvasi</last_name>
	<suffix></suffix>
	<first_name_fa>الناز</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بلواسی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9600319475328460032950</code>
	<orcid>9600319475328460032950</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran </affiliation>
	<affiliation_fa>گروه فیزیک‌ پزشکی، دانشکده پزشکی، دانشگاه علوم ‌پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Abas</first_name>
	<middle_name></middle_name>
	<last_name>Haghparast</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حق پرست</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>9600319475328460032951</code>
	<orcid>9600319475328460032951</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Medical Physics, Faculty of Medicine, Kermanshah University of Medical Sciences, Kermanshah, Iran</affiliation>
	<affiliation_fa>گروه فیزیک‌ پزشکی، دانشکده پزشکی، دانشگاه علوم ‌پزشکی کرمانشاه، کرمانشاه، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>payman</first_name>
	<middle_name></middle_name>
	<last_name>Hejazi</last_name>
	<suffix></suffix>
	<first_name_fa>پیمان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حجازی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hejazip@semums.ac.ir</email>
	<code>9600319475328460032952</code>
	<orcid>9600319475328460032952</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Dept of Medical Physics, Faculty of Medicine, Semnan University of Medical Sciences, Semnan, Iran </affiliation>
	<affiliation_fa>گروه فیزیک‌ پزشکی، دانشکده پزشکی، دانشگاه علوم ‌پزشکی سمنان، سمنان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
