<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Ilam University of Medical Sciences</title>
<title_fa>مجله دانشگاه علوم پزشکی ایلام</title_fa>
<short_title>J. Ilam Uni. Med. Sci.</short_title>
<subject>Medical Sciences</subject>
<web_url>http://sjimu.medilam.ac.ir</web_url>
<journal_hbi_system_id>96</journal_hbi_system_id>
<journal_hbi_system_user>journal96</journal_hbi_system_user>
<journal_id_issn>1563-4728</journal_id_issn>
<journal_id_issn_online>2588-3135</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>doi</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>24</volume>
<number>5</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی کارایی فرآیند الکتروفنتون در حذف بارآلی شیرابه مرکز دفن شهر تهران</title_fa>
	<title>Performance of Electro-Fenton Process For the  Removal of COD From Landfill  Leachate in Tehran</title>
	<subject_fa>بهداشت محیط</subject_fa>
	<subject>Environmental health</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;&lt;em&gt;مقدمه:&lt;/em&gt;&lt;/strong&gt; آلودگی ناشی از شیرابه یکی از اصلی ترین مشکلات مراکز دفن مواد زائد شهری است. استفاده مستقیم روش های بیولوژیکی به دلیل غلظت بالای &lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt; و وجود ترکیبات سمی بسیار دشوار است لذا هدف از این تحقیق تعیین پارامترهای بهینه فرآیند الکتروفنتون در کاهش بار آلی شیرابه مرکز دفن مواد زائد شهری شهر تهران است .&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;&lt;em&gt;مواد و روش ها:&lt;/em&gt;&lt;/strong&gt; پژوهش حاضر در مقیاس آزمایشگاهی به صورت ناپیوسته انجام گرفته است. تصفیه شیرابه با کمک فرآیند الکتروفنتون در یک راکتور الکترولیت ناپیوسته انجام گرفت. تاثیر پارامترهای طراحی چون زمان ماند(40 ، 30 ، 20 ، 10 دقیقه)، &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; اولیه(3 ؛ 5؛ 8)، غلظت اولیه &lt;span dir=&quot;LTR&quot;&gt;H&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;2&lt;/sub&gt;&lt;/span&gt;(&lt;span dir=&quot;LTR&quot;&gt;g/L&lt;/span&gt; 2 &amp;ndash; 5/1 &amp;ndash; 1)، دانسیته جریان الکتریکی(&lt;span dir=&quot;LTR&quot;&gt;mA/cm&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;9/4 &amp;ndash; 9/3 &amp;ndash; 9/2 ) و غلضت&amp;nbsp; بار آلی شیرابه(&lt;span dir=&quot;LTR&quot;&gt;mg/L&lt;/span&gt; 14900&amp;plusmn;37150 :&lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt;) در کارایی فرآیند الکتروفنتون مورد بررسی قرار گرفت.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;&lt;em&gt;یافته های پژوهش:&lt;/em&gt;&lt;/strong&gt; بر طبق نتایج به دست آمده روش الکتروفنتون با حفظ شرایط بهینه واکنش می تواند به طور موثر در تصفیه شیرابه موثر باشد. شرایط بهینه فرآیند در زمان تماس 20 دقیقه، دانسیته جریان الکتریکی: &amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;mA /cm&lt;sup&gt;2&lt;/sup&gt;&lt;/span&gt;9/4، غلظت &lt;span dir=&quot;LTR&quot;&gt;H&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;2&lt;/sub&gt;&lt;/span&gt; برابر با &lt;span dir=&quot;LTR&quot;&gt;g/L&lt;/span&gt; 5/1و در &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; اولیه برابر با 3 به دست آمد. طبق شرایط فوق راندمان کاهش &lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt; در شیرابه میزان 2/87 درصد به دست آمد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;&lt;em&gt;بحث و نتیجه گیری:&lt;/em&gt;&lt;/strong&gt; بر اساس نتایج به دست آمده تکنولوژی الکتروفنتون به طور موثری با تولید عامل اکسیداسیون پیشرفته در محل، غلظت های بالای بار آلی شیرابه را کاهش می دهد و برای تجزیه فاضلاب حاوی &lt;span dir=&quot;LTR&quot;&gt;COD&lt;/span&gt; بالا می تواند به عنوان پیش تصفیه به کار رود و باعث بهبود قابلیت تصفیه پذیری زیستی شیرابه نیز می گردد.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;em&gt;Introduction&lt;/em&gt;: Leachate contamination is one of the major problems caused by landfilling. high concentrations of COD and existence of toxic compounds in landfill leachate and makes it difficult for direct biodegradation. This study aims to optimize the operational parameters of electro-Fenton process for COD removal from landfill leachate in Tehran.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;em&gt;Materials &amp; methods&lt;/em&gt;: The experiments were performed at bench scale using a batch reactor&lt;span dir=&quot;RTL&quot;&gt;.&lt;/span&gt; Treatment of landfill leachate by electro-Fenton (E-Fenton) method was carried out in an electrolytic reactor. Moreover, the effect of operations such as reaction time, initial pH, initial H&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;2&lt;/sub&gt; concentration, electrical current on the efficiency of E-Fenton process were investigated.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;em&gt;Finding&lt;/em&gt;s: The results revealed that (E-Fenton) process can be used for the efficient treatment of landfill leachate applying the proper operating conditions. The best removal efficiency was obtained within 30 min with constant DC current value of 4.9 mA /cm&lt;sup&gt;2&lt;/sup&gt;, H&lt;sub&gt;2&lt;/sub&gt;O&lt;sub&gt;2&lt;/sub&gt; concentration is 1.5gL&lt;sup&gt;&amp;minus;&lt;/sup&gt;&lt;sup&gt;1&lt;/sup&gt; and the initial pH value is 3. COD removal of 87.2% was obtained in these operational conditions.&lt;/p&gt;

&lt;p&gt;&lt;/p&gt;

&lt;p&gt;&lt;em&gt;Discussion &amp; conclusions:&lt;/em&gt; According to the obtained results, E-Fenton technology is able to produce sufficient amounts of advanced oxidants in situ to degrade great COD of leachate. In addition, (E-Fenton) process has been reported as one of the most appropriate pretreatment systems for degradation COD of leachate concentrates. This process&amp;nbsp; improve biodegradability of the landfill leachate.&lt;/p&gt;
</abstract>
	<keyword_fa>شیرابه, مرکز دفن شهری, الکتروفنتون, اکسیداسیون پیشرفته, حذف COD, بار آلی, تهران</keyword_fa>
	<keyword>Landfill leachate, Electro-fenton, Advanced oxidation, COD removal, Tehran</keyword>
	<start_page>31</start_page>
	<end_page>41</end_page>
	<web_url>http://sjimu.medilam.ac.ir/browse.php?a_code=A-10-263-3&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Bijan</first_name>
	<middle_name></middle_name>
	<last_name>Bina</last_name>
	<suffix></suffix>
	<first_name_fa>بیژن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بینا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>bbina123@yahoo.com</email>
	<code>9600319475328460033017</code>
	<orcid>9600319475328460033017</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Environmental Health Engineering, Faculty of Health, Esfahan University of Medical Sciences, Esfahan, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط،دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Kamyar</first_name>
	<middle_name></middle_name>
	<last_name>Yaghmaeian</last_name>
	<suffix></suffix>
	<first_name_fa>کامیار</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یغماییان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>k_yaghmaeian@yahoo.com</email>
	<code>9600319475328460033018</code>
	<orcid>9600319475328460033018</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Dept of Environmental Health Engineering, Faculty of Health, Tehran University of Medical Sciences, Tehran, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط، دانشکده بهداشت، دانشگاه علوم پزشکی تهران، تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Maryam</first_name>
	<middle_name></middle_name>
	<last_name>Meserghani</last_name>
	<suffix></suffix>
	<first_name_fa>مریم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مصرقانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_eserghany@yahoo.com</email>
	<code>9600319475328460033019</code>
	<orcid>9600319475328460033019</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Dept of Environmental Health Engineering, Faculty of Health, Esfahan University of Medical Sciences, Esfahan, Iran</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت محیط،دانشکده بهداشت، دانشگاه علوم پزشکی اصفهان، اصفهان، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
