[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
Publication Ethics::
Peer Review Process::
Indexing Databases::
For Authors::
For Reviewers::
Subscription::
Contact us::
Site Facilities::
::
Google Scholar Metrics

Citation Indices from GS

AllSince 2019
Citations62433553
h-index2719
i10-index18377

..
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Registered in

AWT IMAGE

AWT IMAGE

..
:: Volume 22, Issue 2 (6-2014) ::
Journal of Ilam University of Medical Sciences 2014, 22(2): 24-31 Back to browse issues page
Investigation observation standards of security and dosimetry at x-ray imaging center hospitals Subsidiary Ilam University of medical sciences
J Amiri , Sh Amiri , P Tork , M Abbasi , S p Shirmardi * 1
1- , p_shirmardi@aut.ac.ir
Abstract:   (10907 Views)
Investigation observation standards of security and dosimetry at x-ray imaging center hospitals Subsidiary Ilam University of medical sciences Jamal Amiri 1, Shahin Amiri2, Parvin Tork1,Mohmad hasan Abbasi 1, Seyed Pezhman Shirmardi *3 Introduction: Standards observation in imaging centers cause to patient dose reduction in patients and improving image quality. Identification standards and determine the gap own facilities with standard centers is a necessity for standardization. In this article, Standards level in imaging centers have been studied in Ilam province. Materials & Methods: Dose was measured in the controlled, monitored and uncontrolled region for each center. Czech list contains 210 items were prepared by using standard values in the world and Iran. Separately, Czech list were completed for each center. Level standard calculated at sections: building and construction, Preparation and usage of equipment, Protection of staff and patients, Patient rights and staff salaries for all hospitals and presented as percentage of standard. Level of patient information has been checked about radiation effects by using the questionnaire. Findings: Level of dose were standard in controlled monitored and uncontrolled region all of centers. Generally the level standards in Ilam imaging centers were obtained at sections: Building and construction 64.9 ℅, Preparation and usage of equipment 69.4℅, Protective staff and patients 80.03℅, Rights of patients 81.7℅ and staff rights almost 100%. Patient imaging centers were aware of effects of radiation on cell were 28%. Conclusion: In this study, the level of standard and distance to the full the level of standardization Were determined for all centers.The level of gap with completely standardization of imaging centers in the province is building and construction section35.1℅, preparing and application of equipment 30.6℅, Protection of staff and patients 19.97℅, Patient rights 18.3%. As well as patient imaging centers not informed about the effects of radiation on cells were 72%.
Keywords: Standard imaging centers, imaging, Ilam hospitals
Full-Text [PDF 1165 kb]   (6810 Downloads)    
Type of Study: Research | Subject: Medical physics
Received: 2013/12/15 | Accepted: 2014/05/31 | Published: 2014/06/9
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML   Persian Abstract   Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

amiri J, amiri S, tork P, abbasi M, shirmardi S P. Investigation observation standards of security and dosimetry at x-ray imaging center hospitals Subsidiary Ilam University of medical sciences . J. Ilam Uni. Med. Sci. 2014; 22 (2) :24-31
URL: http://sjimu.medilam.ac.ir/article-1-1404-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 22, Issue 2 (6-2014) Back to browse issues page
مجله دانشگاه علوم پزشکی ایلام Journal of Ilam University of Medical Sciences
Persian site map - English site map - Created in 0.15 seconds with 41 queries by YEKTAWEB 4643